Heat pump chiller application as for total control.
VORTEX FLOW METER
SLK
Flow Range: 0.4 to 90 L/min
Material: PFA
Connection Size: 05, 08, 10, 15, 20
Connection Style: Tube
Power supply voltage: 12 to 24V. DC
Output: Current 4 to 20mA
VORTEX FLOW METER
SLK
Flow Range: 0.5 to 90 L/min
Material: PFA
Connection Size: 05, 08, 10, 15, 20
Connection Style: Tube
Power supply voltage: 12 to 24V. DC
Output: Pulse
VORTEX FLOW SENSOR
PLK, VLK
Flow Range: 60 to 550 L/min
Material: PPS, SUS
Connection Size: 40, 50 (PLK)
Connection Size: 10, 15, 20, 25, 32, 40, 50 (VLK)
Connection Style: Wafer, Tapered male screw(VLK)
Power supply voltage: 24V. DC
Output: Current 4 to 20mA
VORTEX FLOW SENSOR
JLK
Flow Range: 3 to 220 L/min
Material: PPS
Connection Size: 10, 15, 20, 25, 32
Connection Style: Pipe
Power supply voltage: 12 to 24V. DC
Output: Current 4 to 20mA
SOLENOID VALVES
HEV
This small solenoid valve is used for feed water,
cooling water, and hot water circuits of the hot water
supply unit.
A bronze casting type are prepared as the body
material.
EXPANSION VALVES
WHX
R22,R134a,R404A,R407C
Refrigeration display case, commercial refrigerator, freezer, air conditioning, reefer, etc.
ELECTRONIC EXPANSION VALVES
UKV, VKV, PKV, AKV
R22, R134a, R404A, R407C, R410A
Application: Wide range of air conditioning and refrigeration equipment.
Bi-Flow capability. (UKV, VKV, AKV)
EXPANSION VALVES
ATX
R22,R134a,R404A,R407C
General refrigeration and air conditioning system.
EXPANSION VALVES
BHX
R22,R134a
General refrigeration and air conditioning system.
VORTEX FLOW METER
QLK, WLK
Flow Range: 4 to 550 L/min
Material: PPS
Connection Size: 10, 15, 20, 35, 32, 40, 50
Connection Style: Pipe, Wafer, Tapered male screw(VLK)
Power supply voltage: 12 to 24V. DC
Output: Current 4 to 20mA or None
GENERAL-PURPOSE DIGITAL CONTROLLER
ONE
Current input (4 to 20mA. DC)
Remote indications and monitoring can be done by combining with type LK series vortex flow sensor, type XSK pressure sensor, type RNE resistivity meter, conductivity meter, etc.
SOLENOID VALVES FOR REFRIGERANT
SEV
For non-corrosive refrigerant (liquid or gas) in refrigeration
units. Also available for air application.
Pilot operated, 2-way, normally closed valve.
ELECTRONIC EXPANSION VALVES
JKV
For High Pressure
Used for CO2 Refrigerant.
Available for extreme high pressure.
BI-FLOW SOLENOID VALVES
BPV
Bi-flow controlling applicable.
Developed for the purpose of simplification of complicated refrigeration circuit
SOLENOID VALVES
HPV
For High Pressure
Control appliances for hot water supply units by CO2 Refrigerant
4-WAY REVERSING VALVES
STF,VHV
suitable for heat pump applications
STF: Port Size 8 to 50
VHV: Port Size 60 / R410A
3-WAY CHANGE-OVER VALVE
RKV
Control appliance for changing over flow direction in two evaporator type household refrigerator.
EXPANSION VALVES
TCX
R22 BI-FLOW
Heat pump air conditioner
SOLENOID VALVES FOR REFRIGERANT
TEV, VPV
Compactly designed for use in small appliances
Direct-operated, pilot operated, 2-way, normally closed valve. Normally open type is available.